NAME | SYNOPSIS | DESCRIPTION | EXAMPLES | FILES | BUGS | COLOPHON |
|
RAID6CHECK(8) System Manager's Manual RAID6CHECK(8)
raid6check - check MD RAID6 device for errors aka Linux Software RAID
raid6check <raid6 device> <start stripe> <number of stripes>
RAID6 devices in which one single component drive has errors can use
the double parity in order to find out which component drive. The
"raid6check" tool checks, for each stripe, the double parity
consistency, reports mismatches and, if possible, which component
drive has the mismatch. Since it works at stripe level, it can
report different drives with mismatches at different stripes.
"raid6check" requires a non-degraded RAID6 MD device as first
parameter, a starting stripe (usually 0) and the number of stripes to
be checked. If this third parameter is also 0, it will check the
array up to the end.
"raid6check" will start printing information about the RAID6, then
for each stripe, it will report the parity rotation status. In case
of parity mismatches, "raid6check" reports, if possible, which
component drive could be responsible. Otherwise it reports that it is
not possible to find the component drive.
If the given MD device is not a RAID6, "raid6check" will, of course,
not continue.
If the RAID6 MD device is degraded, "raid6check" will report an error
and it will not proceed further.
No write operations are performed on the array or the components.
Furthermore, the checked array can be online and in use during the
operation of "raid6check".
raid6check /dev/md0 0 0
This will check /dev/md0 from start to end.
raid6check /dev/md3 0 1
This will check the first stripe of /dev/md3.
raid6check /dev/md1 1000 0
This will check /dev/md1 from stripe 1000 up to the end.
raid6check /dev/m127 128 256
This will check 256 stripes of /dev/md127 starting from stripe 128.
raid6check /dev/md0 0 0 | grep -i error > md0_err.log
This will check /dev/md0 completely and create a log file only with
errors, if any.
"raid6check" uses directly the component drives as found in /dev.
Furthermore, the sysfs interface is needed in order to find out the
RAID6 parameters.
Negative parameters can lead to unexpected results.
It is not clear what will happen if the RAID6 MD device gets degraded
during the check.
The latest version of raid6check should always be available from
http://www.kernel.org/pub/linux/utils/raid/mdadm/
Related man pages:
mdadm(8) mdmon(8), mdadm.conf(5), md(4).
This page is part of the mdadm (Tool for managing md arrays in Linux)
project. Information about the project can be found at
⟨http://neil.brown.name/blog/mdadm⟩. If you have a bug report for
this manual page, send it to linux-raid@vger.kernl.org. This page
was obtained from the project's upstream Git repository
⟨https://github.com/neilbrown/mdadm.git⟩ on 2018-02-02. (At that
time, the date of the most recent commit that was found in the repos‐
itory was 2017-10-02.) If you discover any rendering problems in
this HTML version of the page, or you believe there is a better or
more up-to-date source for the page, or you have corrections or
improvements to the information in this COLOPHON (which is not part
of the original manual page), send a mail to man-pages@man7.org
v1.0.0 RAID6CHECK(8)